Moonbase
← Back to Awards
R01NIH · NATIONAL INSTITUTE OF NEUROLOGICAL DISORDERS AND STROKENIH

3-D Tractography Focused Ultrasound Ablation for Essential Tremor

Krishna, Vibhor (Contact)·UNIV OF NORTH CAROLINA CHAPEL HILL, NC·2022–2027·ACTIVE
Donate

INSTITUTION

UNIV OF NORTH CAROLINA CHAPEL HILL, NC

PRINCIPAL INVESTIGATOR

Krishna, Vibhor (Contact)

FUNDING

$479K

YEAR

2022

MOONBASE SCORE

Still being scored

LOADING MOONBASE SCORE

Abstract

PROJECT SUMMARY Essential tremor (ET) is a common neurological disorder and a leading cause of functional and psychological disabilities that can be difficult to suppress with oral medications, many of which have considerable side effects limiting adequate dosing. As a result, up to 20% of ET patients cannot achieve satisfactory control of their symptoms and must consider interventional options. Focused ultrasound ablation (FUSA) of the ventral intermediate nucleus (Vim) is an FDA-approved and Medicare-reimbursed procedure for ET resistant to medications that can selectively ablate the brain area associated with tremor without the need for surgical incisions or anesthesia. The success of Vim-FUSA depends on the ability to accurately ablate 70% of the Vim volume without lesioning neighboring structures, a goal that is complicated by technical challenges in three critical phases of the procedure: planning (identifying the Vim location and extension); delivery (ablating the Vim volume with adequate accuracy); and monitoring (confirming Vim ablation with reliable intraoperative imaging). We propose to advance Vim-FUSA with the support of 3-D tractography, a neuroimaging technique to visually represent nerve tracts within the brain. We hypothesize that 3-D tractography Vim-FUSA will improve the Vim ablation compared to standard Vim-FUSA and prove safe and feasible in the clinical setting. We also hypothesize that intraoperative magnetic resonance (i-MR) monitoring will differentiate ablated tissue from immediate perilesional edema and accurately predict the Vim-FUSA clinical outcomes. Aim 1. Estimate and characterize the improvement in Vim ablation achieved with 3-D tractography Vim-FUSA vs. standard Vim-FUSA in an experimental controlled animal study. Through an experimental animal study, we will characterize the Vim ablation delivered with 3-D tractography Vim-FUSA in one hemisphere (experimental group) vs. standard Vim-FUSA in the opposite hemisphere (control group). Aim 2. Test safety, feasibility, and preliminary efficacy, and estimate effect size of 3-D tractography Vim-FUSA in a phase-II, two-groups, pre-post interventional human study. In a human study, we will test the safety and feasibility of ablating 70% of the Vim volume while checking for side effects with intraoperative clinical testing. Tremor assessments will be videotaped at baseline and 12 weeks and compared, in a blinded fashion, with age-sex matched controls randomly selected from the video repository of the two FDA-regulated studies of standard Vim-FUSA at baseline and 12 weeks. Aim 3 (Exploratory). Assess the accuracy of i-MR in differentiating tissue ablation from immediate perilesional edema and its utility in predicting Vim-FUSA clinical outcomes. In the experimental animal study, we will estimate and compare the accuracy of conventional and non-conventional i-MR in differentiating tissue necrosis from perilesional edema. In the interventional human study, we will evaluate the utility of i-MR in predicting Vim-FUSA clinical outcomes.

R01NATIONAL INSTITUTE OF NEUROLOGICAL DISORDERS AND STROKEClinical Neuroscience and Neurodegeneration Study Section[CNN]throughplanningbrainhumanextensioncomparedmedicaredifferentiatingsummarysfdperilesionallesioningprocedureablatedhemispherebaselineresistantneuroimagingconfirmingedemareimbursed

Are you the primary organization running this research?

The two tools below are built for the principal investigator & host institution behind this project.