ANNOUNCEMENT

NOBEL PRIZE 2026

This year's laureates, their fields, and the discoveries that earned them the prize.Live nowSee the winners
Moonbase
← Back to Awards
NIHNATIONAL INSTITUTE OF BIOMEDICAL IMAGING AND BIOENGINEERINGR01

Development of a Video-based Personal Protective Equipment Monitoring System

Completed
Institution
Children's Research Institute, DC
Principal investigator
Randall S. Burd
Funding
$480K
Duration
2023–2026
Open portfolio

Moonbase score

Still being scored

Abstract

PROJECT SUMMARY During the COVID-19 pandemic, healthcare workers (HCWs) have had a more than 11-fold higher infection risk than the general population. Several risk factors for COVID-19 infection among HCWs have been identified, including the lack of personal protective equipment (PPE) and inadequate PPE use. Among these factors, the inadequate use of PPE has been associated with a one-third higher risk of infection. Given the high incidence of infection, there is a critical need to address the challenges of monitoring and promoting adherence with appropriate PPE use among HCWs. The long-term goal of this research is to reduce workplace-acquired infections in HCWs by improving adherence to appropriate PPE use in settings at high risk of transmission. The overall objectives of this proposal are to design, implement, and test a system (Computer-Aided PPE Nonadherence Monitoring and Detection—CAPPED) that (1) tracks the team’s PPE adherence using computer vision and (2) highlights episodes of potential PPE nonadherence on a video-monitoring system. Our central hypothesis is that continuous monitoring of PPE use by multiple HCWs is a complex, cognitively demanding, and error-prone task unaddressed by current methods for monitoring PPE adherence. The rationale for this proposal is that enhanced recognition of PPE nonadherence is a requirement for reducing transmissible infections in HCWs. Guided by preliminary data, the central hypothesis will be tested by pursuing two specific aims: (1) design and implement a computer vision system (CAPPED) for recognizing PPE nonadherence in a dynamic, team-based setting, and (2) compare human performance during simulated resuscitations using direct observation, basic video surveillance, and computer-aided monitoring (CAPPED system). For the first Aim, machine learning approaches will be applied to recognize the type of nonadherent PPE (headwear, eyewear, mask, gown, gloves) and the category of nonadherence (absent or inadequate). Under the second Aim, a customizable visual interface will be designed and evaluated for monitoring and spotlighting PPE nonadherence with a human-in-the-loop. The proposed research is innovative because it addresses the challenges of simultaneously identifying nonadherence with several types of PPE used by multiple individuals in a dynamic setting. This proposed research is significant because it is expected to reduce infection transmission to HCWs by tracking and eventually alerting them to nonadherent PPE use. The results of this research are expected to positively impact the workplace safety of HCWs by addressing the limitations of current approaches to PPE monitoring.

Research team

  • Randall S. BurdPI
  • Marius George LinguraruPI
  • Ivan MarsicPI
  • Aleksandra SarcevicPI

LOADING MOONBASE SCORE

R01NATIONAL INSTITUTE OF BIOMEDICAL IMAGING AND BIOENGINEERINGClinical Informatics and Digital Health Study Section[CIDH]infectionmonitoringcomputer visionadherencenonadherencecomputer-aideddesign implementinadequate

Questions for Children's Research Institute

Answered by the team behind this research.

Same researchers, same institution, same topic, scored first.