Supporting more accurate pulse oximetry for every patient
- Institution
- Icahn School of Medicine at Mount Sinai, NY
- Principal investigator
- Mark S Rea
- Funding
- $574K
- Duration
- 2022–2026
Moonbase score
Still being scored
Abstract
Pulse oximeters provide indirect evaluations of blood oxygen concentration (SpO2) and are widely used throughout the medical professions for diagnosing and monitoring respiratory anomalies in patients. Research shows that commercially available pulse oximeters systematically overestimate true arterial blood oxygen saturation (SaO2) due to the concentration of melanin in the skin. This overestimation in SpO2 puts patients at a greater risk for not meeting the criteria for hospitalization or initiation of ventilator support, which increases risk for mortality or morbidity. No published explanations exist for this well-documented observation and, indeed, the available literature often contrarily states that pulse oximeter measurements are not affected by skin pigmentation. Our theoretical analysis and pilot research, however, demonstrate that the overestimation is due to the use of broadband light-emitting diode (LED) light sources. The broad spectral bandwidths of these LEDs interact with the spectral absorption of melanin concentration in skin to systematically shift the oximeter calibration. This shift causes artificially high values of SpO2 at low blood concentrations of O2, particularly in skin with high melanin concentration. The 3 proposed aims will extend our efforts to date, providing a scientific foundation for eliminating this error and to foster development and promotion of simple, inexpensive, and accurate pulse oximeters. In Aim 1, we will: (a) determine if there are other spectrally-dependent constituents in the finger that change with each pulse; (b) determine how light-source bandwidth interacts with melanin, including whether there are other pulse-dependent changes in spectral transmission through the fingers, and how sensitive SpO2 measurements are to light source bandwidth; (c) specify the practical peak wavelength and spectral bandwidth needed for bias-free pulse oximetry; and (d) fabricate an optimized light source that provides bias-free pulse oximeter measurements for testing in Aim 2. In Aim 2, we will demonstrate that the finger probe developed in Aim 1d provides bias-free pulse oximeter measurements (SpO2) that do not overestimate true arterial oxygen saturation measurements (SaO2) at low blood concentrations of O2. In Aim 3, which will not employ human subjects as in Aims 1 and 2, we will translate our findings (i.e., print, in-person, and social media) to physicians, hospitals, and health care facilities. As part of Aim 3, we will reach out to healthcare professionals to ensure they are aware of the problems with existing commercial pulse oximeters and introduce them to bias-free pulse oximeters once they are available. Finally, we will license the technology to major manufacturers of pulse oximeters to facilitate translation.
Research team
- Mariana Gross FigueiroPI
- Carol R HorowitzPI
- Mark S ReaPI
- Lynne D. RichardsonPI
LOADING MOONBASE SCORE
Questions for Icahn School of Medicine at Mount Sinai
Answered by the team behind this research.
No questions yet. Sign in to ask the first one
Related grants
Same researchers, same institution, same topic, scored first.
- NIH · Icahn School of Medicine at Mount SinaiNot yet scored
All of Us Research Program New York Consortium
Carol R Horowitz · $500K · 2024–2026
- NIH · Icahn School of Medicine at Mount SinaiNot yet scored
The Institute for Health Equity Research Catalyst Center
Sidney H Hankerson · $760K · 2024–2029
- NIH · Icahn School of Medicine at Mount SinaiNot yet scored
Filtered eyewear to prevent light-induced melatonin suppression while maintaining visual performance and alertness in night-shift working nurses
Mariana Gross Figueiro · $671K · 2023–2027