NIHNATIONAL INSTITUTE OF BIOMEDICAL IMAGING AND BIOENGINEERINGR44

High-Resolution Direct-Conversion X-ray Detectors for Low-Dose Imaging

Active
Institution
CAPESYM, INC., MA
Principal investigator
Amlan Datta
Funding
$925K
Duration
2025–2027

Moonbase score

Still being scored

Abstract

Project Summary/ Abstract This project aims to develop and validate high-performance, low-cost direct-conversion X-ray imaging technology based on perovskite sensors for medical imaging applications. Current X-ray imaging faces fundamental limitations in achieving both high spatial resolution and detection efficiency, leading to suboptimal diagnostic accuracy and increased radiation exposure. The proposed Flat Panel X-ray Imagers (FPXIs) address these challenges through superior X-ray sensitivity, exceptional spatial resolution, and high contrast-to-noise ratio, enabling enhanced diagnostic capabilities while reducing patient radiation exposure. The research objectives include: (1) optimizing perovskite sensor film architecture for uniform large-area coverage while maintaining high sensitivity-to-dark-current ratios, (2) developing full- scale detector prototypes, and (3) conducting comprehensive validation studies. The research methodology combines advanced materials engineering and fabrication techniques, and systematic evaluation. Key innovations include ultra-high purity material synthesis, optimized large-area sensor deposition, and novel charge transport architecture. The technology enables significant radiation dose reduction while improving image quality across various medical applications including mammography, general radiography, and tomosynthesis. This development addresses critical healthcare needs by potentially improving early cancer detection capabilities, reducing radiation exposure risks, and lowering healthcare costs through more affordable imaging systems. The successful completion will provide healthcare providers with superior diagnostic tools while enhancing patient safety through reduced radiation exposure.

LOADING MOONBASE SCORE

R44NATIONAL INSTITUTE OF BIOMEDICAL IMAGING AND BIOENGINEERINGSpecial Emphasis Panel[ZEB1 OSR-E (M2)]perovskitediagnosticradiationsuperiorradiation exposurespatial resolutionx-rayexposure

Questions for Capesym, Inc.

Capesym, Inc. hasn't set up its Moonbase portfolio yet, so questions about this research can't be asked here.

Same topic, scored first.