Moonbase
← Back to Funding Opportunities
SAM.govVETERANS AFFAIRS, DEPARTMENT OF — VETERANS AFFAIRS, DEPARTMENT OF

H156--WNY Chute, Barrier, & Door Inspections

Posted Aug 26, 2026·open

AGENCY

VETERANS AFFAIRS, DEPARTMENT OF

PROGRAM

Combined Synopsis/Solicitation

AMOUNT

CLOSES

Sep 1, 2026

Description

WNY Chute, Barrier, & Door Inspections Description This is a combined synopsis/solicitation for commercial products and commercial services prepared in accordance with the format in Revolutionary FAR Overhaul (RFO) in Federal Acquisition Regulation (FAR) subpart 12.202, Streamlined Procedures for Evaluation and Solicitation for Commercial Products and Commercial Services, as supplemented with additional information included in this notice. This announcement constitutes the only solicitation; quotes are being requested, and a written solicitation document will not be issued. This solicitation is issued as an RFQ. The solicitation document and incorporated provisions and clauses are those in effect through Federal Acquisition Circular 2026-01. This solicitation is set aside for SDVOSBs. The associated North American Industrial Classification System (NAICS) code for this procurement is 541350- Building Inspection Services, with a small business size standard of $11.5 million. The FSC/PSC is H156. The Veterans Health Administration of Batavia Veterans Affairs Medical Center and Buffalo VA Medical Center has a requirement that requires preventive maintenance, repair, and inspection of laundry/garbage chute systems and annual smoke/fire barrier and door inspections, over a 12-month base period plus four option years. All interested companies shall provide quotations for the following: Supplies/Services Line Item Description Quantity Unit of Measure Unit Price Total Price BASE PERIOD- 09/21/2026 09/20/2027 0001 Batavia VAMC- PM and Inspection for Chute Intake Doors (3 doors, including fusible link, control, and hardware checks) 12 MO 0002 Batavia VAMC- PM and Inspection for Chute Discharge Doors (1 door, including fusible link, control, and hardware checks) 12 MO 0003 Batavia VAMC- Annual Fire Barrier Inspection, Stairwells (5 in Bldg.1, 2 in Bldg.5, 1 in Bldg. 30) 8 EA 0004 Batavia VAMC-Annual Fire Barrier Inspection Vertical Chase (Laundry Chute, Bldg. 1) 1 EA 0005 Batavia VAMC- Annual Fire Barrier Inspection Elevator Shafts (Core Elevator, Bldg.1 & Bldg.5) 2 EA 0006 Batavia VAMC- Annual Fire Barrier Inspection, Building Unions (Bldg.1 2, Bldg.1 3, Bldg.1 4) 3 EA 0007 Batavia VAMC- Annual Smoke Barrier Inspection (Bldg. 1) 10 EA 0008 Batavia VAMC- Annual Swinging Fire Door Inspection (32 in Bldg.1, 6 in Bldg.5, and 1 in Bldg.30) 39 EA 0009 Batavia VAMC- Annual Swinging Smoke Door Inspection (Bldg. 1) 14 EA 0010 Batavia VAMC- Emergency/Unscheduled Repair Labor 1 HR 0011 Buffalo VAMC- PM & Inspection Chute Intake Doors (44 doors, including fusible link, control, and hardware checks) 12 MO 0012 Buffalo VAMC- PM & Inspection Chute Discharge Doors (4 doors, including fusible link, control, and hardware checks) 12 MO 0013 Buffalo VAMC- Annual Fire Barrier Inspection, Stairwells 17 EA 0014 Buffalo VAMC- Annual Fire Barrier Inspection, Vertical Chases (A D Wings, and Nurse Stations A D) 8 EA 0015 Buffalo VAMC- Annual Fire Barrier Inspection, Dumbwaiter Shafts (Pharmacy, SPS Clean, SPS Dirty, Kitchen) 4 EA 0016 Buffalo VAMC- Annual Fire Barrier Inspection, Elevator Shafts (Core, South) 2 EA 0017 Buffalo VAMC- Annual Fire Barrier Inspection, Building Union 1 EA 0018 Buffalo VAMC- Annual Fire Barrier Inspection, Wing Unions (A to E, D to E") 2 EA 0019 Buffalo VAMC- Annual Smoke Barrier Inspection 45 EA 0020 Buffalo VAMC- Annual Fire Door Inspection, Swinging/Sliding/Rolling 212 EA 0021 Buffalo VAMC- Annual Smoke Door Inspection, Swinging/Sliding/Rolling 87 EA 0022 Buffalo VAMC - Emergency/Unscheduled Repair Labor 1 HR 0023 Provide Parts/Material 1 LT Refer to FAR 52.212-1 OPTION PERIOD ONE - 09/21/2027 09/20/2028 1001 Batavia VAMC- PM and Inspection for Chute Intake Doors (3 doors, including fusible link, control, and hardware checks) 12 MO 1002 Batavia VAMC- PM and Inspection for Chute Discharge Doors (1 door, including fusible link, control, and hardware checks) 12 MO 1003 Batavia VAMC- Annual Fire Barrier Inspection, Stairwells (5 in Bldg.1, 2 in Bldg.5, 1 in Bldg. 30) 8 EA 1004 Batavia VAMC-Annual Fire Barrier Inspection Vertical Chase (Laundry Chute, Bldg. 1) 1 EA 1005 Batavia VAMC- Annual Fire Barrier Inspection Elevator Shafts (Core Elevator, Bldg.1 & Bldg.5) 2 EA 1006 Batavia VAMC- Annual Fire Barrier Inspection, Building Unions (Bldg.1 2, Bldg.1 3, Bldg.1 4) 3 EA 1007 Batavia VAMC- Annual Smoke Barrier Inspection (Bldg. 1) 10 EA 1008 Batavia VAMC- Annual Swinging Fire Door Inspection (32 in Bldg.1, 6 in Bldg.5, and 1 in Bldg.30) 39 EA 1009 Batavia VAMC- Annual Swinging Smoke Door Inspection (Bldg. 1) 14 EA 1010 Batavia VAMC- Emergency/Unscheduled Repair Labor 1 HR 1011 Buffalo VAMC- PM & Inspection Chute Intake Doors (44 doors, including fusible link, control, and hardware checks) 12 MO 1012 Buffalo VAMC- PM & Inspection Chute Discharge Doors (4 doors, including fusible link, control, and hardware checks) 12 MO 1013 Buffalo VAMC- Annual Fire Barrier Inspection, Stairwells 17 EA 1014 Buffalo VAMC- Annual Fire Barrier Inspection, Vertical Chases (A D Wings, and Nurse Stations A D) 8 EA 1015 Buffalo VAMC- Annual Fire Barrier Inspection, Dumbwaiter Shafts (Pharmacy, SPS Clean, SPS Dirty, Kitchen) 4 EA 1016 Buffalo VAMC- Annual Fire Barrier Inspection, Elevator Shafts (Core, South) 2 EA 1017 Buffalo VAMC- Annual Fire Barrier Inspection, Building Union 1 EA 1018 Buffalo VAMC- Annual Fire Barrier Inspection, Wing Unions (A to E, D to E") 2 EA 1019 Buffalo VAMC- Annual Smoke Barrier Inspection 45 EA 1020 Buffalo VAMC- Annual Fire Door Inspection, Swinging/Sliding/Rolling 212 EA 1021 Buffalo VAMC- Annual Smoke Door Inspection, Swinging/Sliding/Rolling 87 EA 1022 Buffalo VAMC - Emergency/Unscheduled Repair Labor 1 HR 1023 Provide Parts/Material 1 LT Refer to FAR 52.212-1 OPTION PERIOD TWO- 09/21/2028 09/20/2029 2001 Batavia VAMC- PM and Inspection for Chute Intake Doors (3 doors, including fusible link, control, and hardware checks) 12 MO 2002 Batavia VAMC- PM and Inspection for Chute Discharge Doors (1 door, including fusible link, control, and hardware checks) 12 MO 2003 Batavia VAMC- Annual Fire Barrier Inspection, Stairwells (5 in Bldg.1, 2 in Bldg.5, 1 in Bldg. 30) 8 EA 2004 Batavia VAMC-Annual Fire Barrier Inspection Vertical Chase (Laundry Chute, Bldg. 1) 1 EA 2005 Batavia VAMC- Annual Fire Barrier Inspection Elevator Shafts (Core Elevator, Bldg.1 & Bldg.5) 2 EA 2006 Batavia VAMC- Annual Fire Barrier Inspection, Building Unions (Bldg.1 2, Bldg.1 3, Bldg.1 4) 3 EA 2007 Batavia VAMC- Annual Smoke Barrier Inspection (Bldg. 1) 10 EA 2008 Batavia VAMC- Annual Swinging Fire Door Inspection (32 in Bldg.1, 6 in Bldg.5, and 1 in Bldg.30) 39 EA 2009 Batavia VAMC- Annual Swinging Smoke Door Inspection (Bldg. 1) 14 EA 2010 Batavia VAMC- Emergency/Unscheduled Repair Labor 1 HR 2011 Buffalo VAMC- PM & Inspection Chute Intake Doors (44 doors, including fusible link, control, and hardware checks) 12 MO 2012 Buffalo VAMC- PM & Inspection Chute Discharge Doors (4 doors, including fusible link, control, and hardware checks) 12 MO 2013 Buffalo VAMC- Annual Fire Barrier Inspection, Stairwells 17 EA 2014 Buffalo VAMC- Annual Fire Barrier Inspection, Vertical Chases (A D Wings, and Nurse Stations A D) 8 EA 2015 Buffalo VAMC- Annual Fire Barrier Inspection, Dumbwaiter Shafts (Pharmacy, SPS Clean, SPS Dirty, Kitchen) 4 EA 2016 Buffalo VAMC- Annual Fire Barrier Inspection, Elevator Shafts (Core, South) 2 EA 2017 Buffalo VAMC- Annual Fire Barrier Inspection, Building Union 1 EA 2018 Buffalo VAMC- Annual Fire Barrier Inspection, Wing Unions (A to E, D to E") 2 EA 2019 Buffalo VAMC- Annual Smoke Barrier Inspection 45 EA 2020 Buffalo VAMC- Annual Fire Door Inspection, Swinging/Sliding/Rolling 212 EA 2021 Buffalo VAMC- Annual Smoke Door Inspection, Swinging/Sliding/Rolling 87 EA 2022 Buffalo VAMC - Emergency/Unscheduled Repair Labor 1 HR 2023 Provide Parts/Material 1 LT Refer to FAR 52.212-1 OPTION PERIOD THREE - 09/21/2029 09/20/2030 3001 Batavia VAMC- PM and Inspection for Chute Intake Doors (3 doors, including fusible link, control, and hardware checks) 12 MO 3002 Batavia VAMC- PM and Inspection for Chute Discharge Doors (1 door, including fusible link, control, and hardware checks) 12 MO 3003 Batavia VAMC- Annual Fire Barrier Inspection, Stairwells (5 in Bldg.1, 2 in Bldg.5, 1 in Bldg. 30) 8 EA 3004 Batavia VAMC-Annual Fire Barrier Inspection Vertical Chase (Laundry Chute, Bldg. 1) 1 EA 3005 Batavia VAMC- Annual Fire Barrier Inspection Elevator Shafts (Core Elevator, Bldg.1 & Bldg.5) 2 EA 3006 Batavia VAMC- Annual Fire Barrier Inspection, Building Unions (Bldg.1 2, Bldg.1 3, Bldg.1 4) 3 EA 3007 Batavia VAMC- Annual Smoke Barrier Inspection (Bldg. 1) 10 EA 3008 Batavia VAMC- Annual Swinging Fire Door Inspection (32 in Bldg.1, 6 in Bldg.5, and 1 in Bldg.30) 39 EA 3009 Batavia VAMC- Annual Swinging Smoke Door Inspection (Bldg. 1) 14 EA 3010 Batavia VAMC- Emergency/Unscheduled Repair Labor 1 HR 3011 Buffalo VAMC- PM & Inspection Chute Intake Doors (44 doors, including fusible link, control, and hardware checks) 12 MO 3012 Buffalo VAMC- PM & Inspection Chute Discharge Doors (4 doors, including fusible link, control, and hardware checks) 12 MO 3013 Buffalo VAMC- Annual Fire Barrier Inspection, Stairwells 17 EA 3014 Buffalo VAMC- Annual Fire Barrier Inspection, Vertical Chases (A D Wings, and Nurse Stations A D) 8 EA 3015 Buffalo VAMC- Annual Fire Barrier Inspection, Dumbwaiter Shafts (Pharmacy, SPS Clean, SPS Dirty, Kitchen) 4 EA 3016 Buffalo VAMC- Annual Fire Barrier Inspection, Elevator Shafts (Core, South) 2 EA 3017 Buffalo VAMC- Annual Fire Barrier Inspection, Building Union 1 EA 3018 Buffalo VAMC- Annual Fire Barrier Inspection, Wing Unions (A to E, D to E") 2 EA 3019 Buffalo VAMC- Annual Smoke Barrier Inspection 45 EA 3020 Buffalo VAMC- Annual Fire Door Inspection, Swinging/Sliding/Rolling 212 EA 3021 Buffalo VAMC- Annual Smoke Door Inspection, Swinging/Sliding/Rolling 87 EA 3022 Buffalo VAMC - Emergency/Unscheduled Repair Labor 1 HR 3023 Provide Parts/Material 1 LT Refer to FAR 52.212-1 OPTION PERIOD FOUR - 09/21/2030 09/20/2031 4001 Batavia VAMC- PM and Inspection for Chute Intake Doors (3 doors, including fusible link, control, and hardware checks) 12 MO 4002 Batavia VAMC- PM and Inspection for Chute Discharge Doors (1 door, including fusible link, control, and hardware checks) 12 MO 4003 Batavia VAMC- Annual Fire Barrier Inspection, Stairwells (5 in Bldg.1, 2 in Bldg.5, 1 in Bldg. 30) 8 EA 4004 Batavia VAMC-Annual Fire Barrier Inspection Vertical Chase (Laundry Chute, Bldg. 1) 1 EA 4005 Batavia VAMC- Annual Fire Barrier Inspection Elevator Shafts (Core Elevator, Bldg.1 & Bldg.5) 2 EA 4006 Batavia VAMC- Annual Fire Barrier Inspection, Building Unions (Bldg.1 2, Bldg.1 3, Bldg.1 4) 3 EA 4007 Batavia VAMC- Annual Smoke Barrier Inspection (Bldg. 1) 10 EA 4008 Batavia VAMC- Annual Swinging Fire Door Inspection (32 in Bldg.1, 6 in Bldg.5, and 1 in Bldg.30) 39 EA 4009 Batavia VAMC- Annual Swinging Smoke Door Inspection (Bldg. 1) 14 EA 4010 Batavia VAMC- Emergency/Unscheduled Repair Labor 1 HR 4011 Buffalo VAMC- PM & Inspection Chute Intake Doors (44 doors, including fusible link, control, and hardware checks) 12 MO 4012 Buffalo VAMC- PM & Inspection Chute Discharge Doors (4 doors, including fusible link, control, and hardware checks) 12 MO 4013 Buffalo VAMC- Annual Fire Barrier Inspection, Stairwells 17 EA 4014 Buffalo VAMC- Annual Fire Barrier Inspection, Vertical Chases (A D Wings, and Nurse Stations A D) 8 EA 4015 Buffalo VAMC- Annual Fire Barrier Inspection, Dumbwaiter Shafts (Pharmacy, SPS Clean, SPS Dirty, Kitchen) 4 EA 4016 Buffalo VAMC- Annual Fire Barrier Inspection, Elevator Shafts (Core, South) 2 EA 4017 Buffalo VAMC- Annual Fire Barrier Inspection, Building Union 1 EA 4018 Buffalo VAMC- Annual Fire Barrier Inspection, Wing Unions (A to E, D to E") 2 EA 4019 Buffalo VAMC- Annual Smoke Barrier Inspection 45 EA 4020 Buffalo VAMC- Annual Fire Door Inspection, Swinging/Sliding/Rolling 212 EA 4021 Buffalo VAMC- Annual Smoke Door Inspection, Swinging/Sliding/Rolling 87 EA 4022 Buffalo VAMC - Emergency/Unscheduled Repair Labor 1 HR 4023 Provide Parts/Material 1 LT Refer to FAR 52.212-1 Performance Work Schedule (PWS) SUMMARY: The Contractor shall provide monthly preventative maintenance (PM), repair services, and inspections of laundry & garbage chute systems, and annual smoke & fire barriers, and smoke & fire doors under a 12-month base contract period, including four option years. All services shall be performed at the following addresses- Address: Batavia Veterans Affairs Medical Center (VAMC) 222 Richmond Avenue Batavia, NY 14020 Buffalo VA Medical Center Bailey Avenue Buffalo, NY 14215 Note- The Contractor shall be required to perform and complete all monthly inspections beginning in the same month as the contract award date, unless otherwise directed by the facility. GENERAL: All inspections, testing, adjustments, and reporting shall comply with the latest edition of: National Fire Protection Association (NFPA): NFPA 80 Standard for Fire Doors and Other Opening Protectives, 2025 Edition. NFPA 82 Standard on Incinerators and Waste and Linen Handling Systems and Equipment, 2024 Edition. NFPA 101 Life Safety Code, 2024 Edition. NFPA 105 Standard for Smoke Door Assemblies and Other Opening Protectives, 2025 Edition. Occupational Safety & Health Administration (OSHA): OSHA Title 29, Code of Federal Regulations (CFR) Part 1910 Subpart I Personal Protective Equipment (PPE) (1910.132-1910.140). OSHA Title 29, CFR Part 1910 Subpart J The Control of Hazardous Energy (lockout/tagout) (1910.147). OSHA Title 29, CFR Part 1910, Subpart S Electrical (1910.301-1910.399). Veterans Affairs Western New York Healthcare System (VAWNYHS) Medical Center Policy (MCP): MCP 138-15 Electrical Safety Program. MCP 00-190 Control of Hazardous Energy Program. Should a conflict arise between Veterans Affairs (VA) requirements and nationally recognized codes and standards, the conflict shall be brought to the attention of the Contracting Officers Representative (COR). The resolution of conflict must be made by the VA Authority Having Jurisdiction (AHJ). In the event of a conflict between the text of this document and nationally recognized codes and standards, the nationally recognized codes and standards take precedence. Nothing in this document supersedes applicable laws and regulations unless a specific exemption has been obtained. The selection, assignment, and management of Contractor s employees are the responsibility of the Contractor. The Contactor shall not employ any individual identified as a potential threat to the health, safety, security, and general wellbeing, or operation of the VAMC or its customers and personnel. The Contractor is fully responsible for the performance and conduct of their employees while on VAMC property. The Contractor shall not allow any employee to perform work under this contract while under the influence of alcohol, drugs, incapacitating agent or illness. The gravity chute (Laundry & Trash) systems shall be inspected monthly. During the performance of the annual smoke & fire barrier and smoke & fire door inspections, the Contractor shall utilize existing inspection schedules asdefined by the facilities. The Batavia VAMC inspections for barriers/doors are to be completed entirely in January of each contract year. The Buffalo VAMC inspections are to be completed by floor. Each floor has a designated month they are to be inspected during. These inspections take place during all twelve (12) months of the contract year. These schedules shall not be altered from their monthly schedule The Contractor shall supply all labor, tools, equipment, and PPE required to perform the work identified in this agreement safely, effectively, and timely in accordance with NFPA and OSHA Standards. The Contractor shall provide a technician to perform emergency repairs on all systems covered under this agreement within two (2) hours of receiving a call for service from the designated COR or VAMC representative. The Contractor must be able to provide technicians for emergency call-in service 24 hours a day / 365 days per year. All expenses related to emergency call-ins for service shall not be covered by this agreement, those services shall be funded as a separate requirement either through a modification to this contract or Government Purchase Card (GPC) Purchase Order (PO). The VA agrees to provide Contractor free access to all equipment necessary to conduct work, and free access to all rooms or areas housing such. At any time, the COR may deem any tool, technician, or method unacceptable based on the authority of inspection/acceptance of services. CONTRACTOR QUALIFICATIONS: All Contractor employees shall readily have access to the Codes, Policies, and Regulations listed under B.3.2.B.1./3. of this agreement. Contractor employees who carry out preventive maintenance, inspections, and repairs must have at least two years of field experience servicing all systems covered by this agreement. They are required to provide documentation demonstrating that they meet these experience requirements. All Contractor technicians working on-site shall have completed an OSHA approved 10-hour construction safety training course. SAFETY: In the performance of this contract, the Contractor shall take all precautions necessary to protect persons and property from injury or damage. The COR or designee shall notify the Contractor of any safety issues and the action necessary to correct the issues. Such Notice, when served to the Contractor or their representative at the work site shall be deemed sufficient for the corrective actions to be taken. If the Contractor fails or refuses to comply promptly with notified safety deficiencies, the Contracting Officer (CO) may issue an order stopping all or part of the work and hold the Contractor in default. All work areas must be clean at the close of the day and shall be left in the same condition as before work started. No tools or equipment shall be left unattended. WORK SCHEDULE: The requirements outlined in this PWS shall be performed during regular business hours 7:00 AM to 4:30 PM, Monday through Friday, scheduled at least 72 hours in advance with the COR The following are Federal Holidays observed by the VA and the Contractor shall not expect access to VA facilities or VA staff on these dates unless notified otherwise by the COR. Preventive maintenance or other services are not to be scheduled on these dates: New Year s Day Martin Luther King, Jr. Day Washington s Birthday Memorial Day Juneteenth Independence Day Labor Day Columbus Day Veteran s Day Thanksgiving Day Christmas Day All work activities are not to interfere with patients and/or staff. The VAMC must maintain its operation 24 hours a day / 365 days per year. Therefore, any interruption in service must be scheduled and coordinated with the COR to ensure that no disruptions to VAMC operations occur. The Contractor shall report to the COR before and after performance of service and provide evidence of service performed. If it becomes difficult for the Contractor to complete the required services due to patient care related activities or security issues, the Contractor shall not be obligated to complete testing in the area of concern at the time of their scheduled visit. The Contractor shall be obligated to complete the incomplete portion of their work at the time of the next scheduled visit to the facility. The final authority relative to this decision will be the COR If it becomes difficult for the Contractor to complete the required services due to patient care related activities or security issues, the Contractor shall not be obligated to complete testing in the area of concern at the time of their scheduled visit. The Contractor shall be obligated to complete the incomplete portion of their work at the time of the next scheduled visit to the facility. SITE SPECIFICS: The Batavia VAMC is a multi-building campus. The inspections listed in this PWS are performed throughout Buildings 1, 5, & 30. Building 1 is five (5) stories, comprised of floors G-4. Building 5 is four (4) stories, comprised of floors 1-3. Building 30 is two (2) stories, comprised of floors B-1. The Buffalo VAMC is a single high-rise building. The inspections listed in this PWS are all performed in Building 1. Building 1 is fifteen (15) stories, comprised of floors SB-13. Contractor shall perform monthly inspections and repairs, as needed, on the laundry and trash chute intake and discharge doors. Batavia VAMC: Three (3) intake doors. One (1) discharge door. Buffalo VAMC: Forty-four (44) intake doors. Four (4) discharge doors. Contractor shall perform annual inspections of smoke & fire barriers and doors. Batavia VAMC Building 1: Fire Barriers: Five (5) Stairwells. One (1) Vertical Chase: Laundry Chute. One (1) Elevator Shaft: Core Elevators. Three Building Unions: Building 1 to Building 2. Building 1 to Building 3. Building 1 to Building 4. Ten (10) Smoke Barriers. Thirty-two (32) Fire Doors. Fourteen (14) Smoke Doors. Batavia VAMC Building 5: Fire Barriers:Two (2) Stairwells. One (1) Elevator Shaft: Core Elevator. Six (6) Fire Doors. Batavia VAMC Building 30: Fire Barriers: One (1) Stairwell. One (1) Fire Doors. Buffalo VAMC Building 1: Fire Barriers: Seventeen (17) Stairwells. Eight (8) Vertical Chases: A Wing. B Wing. C Wing. D Wing. Nurse Station A . Nurse Station B . Nurse Station C . Nurse Station D . Four (4) Dumbwaiter Shafts: Pharmacy. SPS Clean. SPS Dirty. Kitchen. Two (2) Elevator Shafts: Core Elevators. South Elevators. One (1) Building Union. Two (2) Wing Unions: A to E . D to E . Forty-five (45) Smoke Barriers. Two hundred twelve (212) Fire Doors. Eighty-seven (87) Smoke Doors. INSPECTIONS: LAUNDRY & GARBAGE CHUTES: Performance of the monthly laundry & garbage chute PM shall consist of the following tasks: Visually inspect all system components for signs of wear or damage. Verify fusible link is present and attached to the discharge door. If fusible link is not present or in need of replacement notify the COR immediately. Inspect condition of fusible link by: Ensuring it is not painted or coated with dust or grease. Evaluate the condition of the chains/cables, s-hooks, eyes, and other devices that operate as a result of the link melting to verify working condition. Every three (3) months simulate a fire in the room by detaching the chain and fusible link from the discharge door and allowing the door to drop. Ensure the door fully closes and latches without assistance. If the door does not fully close or latch notify the COR immediately. When complete, document date the testing was performed. Open the discharge door and reattach chain and fusible link to place chute back into service. Replace the link if damaged or painted with a link of the same size, temperature, and load rating. In the chute discharge rooms: Lightly lubricate hinges on discharge doors as required. Inspect power control center for wear or damage and ensure signal lights are operational. Activate the electromagnet circuit for chute intake doors to be inspected. In the chute intake rooms: Verify the electromagnets on intake doors are engaged and the doors cannot be opened without a key. After verifying the intake door is positively latched, use a key to deactivate the individual electromagnet and perform the required inspections. When complete ensure the door s electromagnet is re-activated and the door is secure. Inspect intake doors for missing hardware and replace as needed. Visually inspect control circuit for loose or frayed wires Inspect for sharp metal edges around intake doors, frames, and openings; repair as needed. Doors that require repair shall remain locked out until repairs can be completed Return inspected chutes system to service by de-activating the electromagnet circuit located in the discharge rooms. Document equipment inspected, faults/repairs (if any), parts required to be ordered and provide the completed form to the COR upon completion. The VA shall be responsible for the payment/ordering of all parts as applicable The VA Medical Center will store all parts for this requirement. Repairs that require parts to be ordered shall be made within five (5) business days of the COR notifying the Contractor of parts and repairs needed. Return trips required to correct deficient work or to complete tasks left unfinished due to Contractor fault or error shall be performed at no additional cost to the Government FIRE BARRIERS: Performance of the annual fire barrier inspections shall consist of the following tasks: Verify the fire barrier is continuous from outside wall to outside wall or from one fire barrier to another, or a combination including continuity through all concealed spaces, such as those found above a ceiling, including interstitial spaces. Verify there are no penetrations on either side of the barrier, removing ceiling tiles where necessary Complete documentation of all fire barriers inspected on forms provided by the VA, to include deficiencies (if any), and the recommended course of corrective action to be taken. Work to repair the fire barriers, if necessary, is included in the overall scope of this requirement but will not be a part of the current PWS task. Any required repairs will be quoted and procured through a modification to this contract SMOKE BARRIERS: Performance of the annual smoke barrier inspections shall consist of the following tasks: Verify the smoke barrier is continuous from an outside wall to an outside wall, from floor to floor, or from smoke barrier to smoke barrier, or by use of any combination thereof. Verify there are no penetrations on either side of the barrier, removing ceiling tiles where necessary. Complete documentation of all smoke barriers inspected on forms provided by the VA, to include deficiencies (if any), and the recommended course of corrective action to be taken. Work to repair the smoke barriers, if necessary, is included in the overall scope of this requirement but will not be a part of the current PWS task. Any required repairs will be quoted and procured through a modification to this contract SWINGING FIRE DOORS: During performance of the annual swinging fire door inspections the Contractor shall visually inspect both sides of the door and verify: Fire rating labels are clearly visible and legible. No open holes or breaks exist on the surfaces of either the door or door frame. Glazing, vision light frames, and glazing beads are intact and securely fastened in place, if so equipped. The door, frame, hinges, hardware, and noncombustible threshold are secured, aligned, and in working order with no visible signs of damage. No parts are missing or broken. When measured on the pull side of the door(s) door clearances do not exceed: For lap-mounted doors, clearance dimensions between the face of the door and the wall surface over which it rests in the closed position shall not exceed 3/8 in. (10 mm). For flush-mounted doors, where doors are installed in frames, clearance dimensions between the vertical and top edges of the doors and the frames shall not exceed 1/8 in. ± 1/16 in. (3.18 mm ± 1.59 mm). Clearance dimensions between the meeting edges of paired doors shall not exceed 1/8 in. ± 1/16 in. (3.18 mm ± 1.59 mm). Clearance under doors, in the closed position, shall not exceed 3/8 in. (10 mm) above raised noncombustible sills and not more than 3/4 in. (20 mm) above the floor where there is no raised noncombustible sill. The self-closing device is operational: that is, the active door completely closes without assistance when operating from the full open position. If a coordinator is installed, the inactive leaf closes before the active leaf. Latching hardware operates and secures the door without assistance when it is in the closed position. Auxiliary hardware items that interfere or prohibit operation are not installed on the door or frame. No field modifications to the door assembly have been performed that void the label. Meeting edge protection, gasketing, and edge seals, where required, are inspected to verify their presence and integrity. Signage affixed to the door meets the following requirements: Combustible materials shall not exceed 5 percent of the area of the face of the door. Attached by adhesive not mechanically fastened. Not installed on the fire rated glazing. Does not impair door operation. Document all doors inspected and deficiencies (if any) on VA provided checklist and deliver to the COR upon the workday s completion. Work to repair the swinging fire doors, if necessary, is included in the overall scope of this requirement but will not be a part of the current PWS task. Any required repairs will be quoted and procured through a modification to this contract HORIZONTALLY SLIDING, VERTICALLY SLIDING, AND ROLLING FIRE DOORS: During performance of the annual horizontal sliding, vertically sliding, and rolling fire door inspections the Contractor shall visually inspect both sides of the door and verify: Fire rating labels are clearly visible and legible. No open holes or breaks exist on the surfaces of either the door or door frame. Slats, end-locks, bottom bar, guide assembly, curtain entry, hood, and flame baffle are correctly installed and intact for rolling steel fire doors. Glazing, vision light frames, and glazing beads are intact and securely fastened in place, if so equipped. Curtain, barrel, and guides are aligned, level, plumb, and true for rolling steel fire doors. Expansion clearance is maintained in accordance with the manufacturer s listing. Drop release arms and weights are not blocked or wedged. Mounting and assembly bolts are intact and secured. Attachments to jambs are with bolts, expansion anchors, or as otherwise required by the listing. No parts are missing or broken Fusible links, if equipped, are in the correct locations; chain/cable, s-hooks, eyes, and so forth are in good condition; the cable or chain is not kinked, pinched, twisted, or inflexible; and links are not painted or coated with dust or grease. Auxiliary hardware items that interfere or prohibit operation are not installed on the door or frame. No field modifications to the door assembly have been performed that void the label. Doors have an average closing speed of not less than six (6) in./sec (152 mm/sec) or more than 24 in./sec (610 mm/sec). Document all doors inspected and deficiencies (if any) on VA provided checklist and deliver to the COR upon the workday s completion. Work to repair the horizontally sliding, vertically sliding, and rolling fire doors, if necessary, is included in the overall scope of this requirement but will not be a part of the current PWS task. Any required repairs will be quoted and procured through a modification to this contract SWINGING SMOKE DOORS: During performance of the annual swinging smoke door inspections the Contractor shall visually inspect both sides of the door and verify. Labels on fire-rated smoke door assemblies are clearly visible and legible and bear the S label marking. Door leaves without fire protection ratings are of a design that resists the passage of smoke. Door frames are labeled or where permitted are of steel construction or of other designs that have been tested and reported by a nationally recognized testing agency in accordance with NFPA 252, UL 10B, or UL 10C. Gasketing along the vertical edges of the door and across the top of the door and, where required, at meeting edges of pairs of doors forms a continuous seal that is not cut, notched, or otherwise modified to accommodate other hardware items. Gasketing materials, where required, are intact and close the gaps between the door and frame to seal the door opening against the passage of smoke. Doors installed in pressurized applications have a bottom seal, where required. Doors equipped with bottom seals th...

Eligibility

Service-Disabled Veteran-Owned Small Business (SDVOSB) Set-Aside (FAR 19.14)

Contact

Yasmin Moses — Contract Specialist

Yasmin.Moses@va.gov

718-584-9000

Additional details

Sub-tier
VETERANS AFFAIRS, DEPARTMENT OF
Office
242-NETWORK CONTRACT OFFICE 02 (36C242)
NAICS code
541350
Set-aside
SDVOSBC
Place of performance
Batavia, 14020
Archived
Dec 1, 2026

Opportunity number: 36C24226Q0687

Search this number on SAM.gov Contract Opportunities for the official listing.