← Back to Funding Opportunities
SAM.govHEALTH AND HUMAN SERVICES, DEPARTMENT OF — FOOD AND DRUG ADMINISTRATION
3D Imaging Microscope System
Posted Sep 8, 2026·open
AGENCY
HEALTH AND HUMAN SERVICES, DEPARTMENT OF
PROGRAM
Combined Synopsis/Solicitation
AMOUNT
—
CLOSES
Sep 14, 2026
Description
SCOPE I. Minimum Performance Requirements/Salient Characteristics Salient Characteristics The contractor shall provide all resources necessary to accomplish the tasks and deliverables described in this statement of work, including the hardware system requirements which are the minimum requirements. Equivalent requirements that differ from these minimum requirements must be justified by the proposing vendor and evaluated by the NFCC prior to purchase. 1.0 General Requirement The National Forensic Chemistry Center (NFCC) requires a Bruker Alicona InfiniteFocus G6 (IFM G6) optical 3D measurement system. This non-contact, optical 3D imaging and measurement system will be used by NFCC's Trace Examination Section (TES) for surface profilometry and difference analysis measurements, including tablet debossing, punch face embossing, surface abrasion, pit measurements, corroded surface analysis, and pharmaceutical packaging topography and print profiling. The system must expand analytical throughput to meet increasing demand for forensic 3D image analysis from law enforcement stakeholders. 2.0 Core Technology and Measurement Principle 2.1 The system shall be based on the principle of Focus Variation Microscopy (FVM), utilizing Bruker Alicona's proprietary Focus Variation algorithms to reconstruct high-resolution 3D surfaces. 2.2 The system must include advanced illumination technology (e.g., ring light, coaxial light) to enable accurate measurement of surfaces with steep angles, up to and exceeding 85 degrees. 2.3 The system must be capable of measuring both form and surface roughness parameters in a single measurement, with all data being co-registered. 2.4 The system must have the ability to measure highly reflective materials without surface treatment. The system must be capable of acquiring accurate 3D topographic data on reflective and specular materials without requiring surface alteration that could compromise the integrity of forensic samples. 2.5 The system must have the capability to capture true-color optical data co-registered with 3D topography. This capability supports surface characterization, documentation, and interpretation of coating or material variations. Many profilometry systems such as systems that use laser or tip technologies do not provide integrated true-color 3D datasets.
Eligibility
No Set aside used
Contact
Additional details
- Sub-tier
- FOOD AND DRUG ADMINISTRATION
- Office
- FDA OFFICE OF ACQ GRANT SVCS
- NAICS code
- 334519
- Set-aside
- NONE
- Place of performance
- Cincinnati, OH, 45237, USA
- Archived
- Sep 29, 2026
Opportunity number: 75F40126Q00383
Search this number on SAM.gov Contract Opportunities for the official listing.